TASK 49-00-00-810-991 APU AUTO Shutdown without Bite Message 1. Possible Causes _______________ - water ingress in Panel 121AL - Panel 108VU 2. Job Set-up Information ______________________ A. Referenced Information ------------------------------------------------------------------------------REFERENCE DESIGNATION ------------------------------------------------------------------------------AMM 31-10-00-700-001 Test Program after Removal/Installation of a VU panel
3. Fault Confirmation __________________ A. Check (1) Do a check for water ingress in Panel 121AL. (2) Dry the panel 108VU. (3) Do the test (Ref. AMM TASK 31-10-00-700-001) for panel 108VU. 4. Fault Isolation _______________ A. If the test fails and/or the APU shutdown without BITE Message: - replace Panel 108VU. B. Do the test as Para. 3.A.
R
EFF : CES
001-003, 051-099, 401-499,
∞ 49-00-00∞∞ ∞ ∞ ∞ Page01/05 ∞ B237 Config-1 Aug
飞行翻译公司 www.aviation.cn 本文链接地址:A319 A320 A321 排故手册 TSM Trouble Shooting Manual 22_部分2.pdf
3. Fault Confirmation __________________ A. Check (1) Do a check for water ingress in Panel 121AL. (2) Dry the panel 108VU. (3) Do the test (Ref. AMM TASK 31-10-00-700-001) for panel 108VU. 4. Fault Isolation _______________ A. If the test fails and/or the APU shutdown without BITE Message: - replace Panel 108VU. B. Do the test as Para. 3.A.
R
EFF : CES
001-003, 051-099, 401-499,
∞ 49-00-00∞∞ ∞ ∞ ∞ Page01/05 ∞ B237 Config-1 Aug
飞行翻译公司 www.aviation.cn 本文链接地址:A319 A320 A321 排故手册 TSM Trouble Shooting Manual 22_部分2.pdf