R R R R R R R R R R
Subtask 36-11-52-440-076 C. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041). Subtask 36-11-52-410-105 D. Close Access (1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR (2) Remove the warning notice(s). Subtask 36-11-52-860-077
R
E. Put the aircraft back to its initial configuration. (1) On the AIR control panel 30VU: - release the ENG BLEED pushbutton switches (OFF legends come on). (2) Do the EIS stop procedure (Ref. TASK 31-60-00-860-002). Subtask 36-11-52-862-064
R
F. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
EFF : CES
ALL
36-11-52
Page 522 Feb 01/04
飞行翻译公司 www.aviation.cn 本文链接地址:A319 A320 A321 飞机维护手册 AMM Aircraft Maintenance Manual 27_部分3.pdf
Subtask 36-11-52-440-076 C. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041). Subtask 36-11-52-410-105 D. Close Access (1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR (2) Remove the warning notice(s). Subtask 36-11-52-860-077
R
E. Put the aircraft back to its initial configuration. (1) On the AIR control panel 30VU: - release the ENG BLEED pushbutton switches (OFF legends come on). (2) Do the EIS stop procedure (Ref. TASK 31-60-00-860-002). Subtask 36-11-52-862-064
R
F. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
EFF : CES
ALL
36-11-52
Page 522 Feb 01/04
飞行翻译公司 www.aviation.cn 本文链接地址:A319 A320 A321 飞机维护手册 AMM Aircraft Maintenance Manual 27_部分3.pdf